Indication
|
Contents
|
Detect contents
|
Check point
|
Method to clear
|
||
|
U11
|
Unable to drain
|
Incase won't detect reset point in 12 min. After starting of drain.
|
■ Is something wrong with the drain hose?
■ Is lint clogging it?
■ Check if condition of the water level detector.
|
After solving problems, open the door and close it, and then restart operation.
|
||
|
U12
|
The door is open
|
Door is opening at start point of the operation.
|
■ Is the door open?
|
Close the door to start operation.
|
||
|
U13
|
Unbalanced load
|
Detect unbalanced load at spin process.
|
■ Chack if clothes are not tangled in the drum. ■ Check if the washer is not installed on an unstable or sloping floor.
|
After solving problems, open the door and close it, and then restart operation.
|
||
|
U14
|
Unable to supply water
|
It's takes over 20 min. to reach specified water level.
|
■ It's takes over 20 min. to reach specified water level.
■ Check if condition of the water valve.
■ Is the filter of the feed valve clogged?
|
After solving problems, open the door and close it, and then restart operation.
|
||
|
U18
|
Drain filter is not set
|
Detect drain filter is securely tightened
|
■ Check if drain filter is securely tightened during the operation.
|
Set the drain filter properly
|
||
|
HO1
|
Water level detector
|
Input frequency from the water level detector is out of rated frequency.
|
■ Check if condition of the connectors.
■ Replace water level detector.
■ Replace PC Board (Power side).
|
Turn off the power
|
||
|
H04
|
Short circuit of power relay on the PC.Board
|
Detect short circuit of the power relay on the PC Board.
|
■ Replace PC Board.
|
Remove the power plug
|
||
|
H05
|
Data shall not be memorized.
|
Data won't saved to the micro processor(In case of service check mode-B).
|
■ Replace PC Board (Power side).
■ Effected service mode (Check mode-B) only.
|
Turn off the power
|
||
|
H07
|
Malfunction of rotary detector.
|
Input signal from the rotary detector when operating the motor shall be occurred out of standard.
|
■ Check if condition of the connector and lead wire of the rotary detector.
■ Replace the motor.
■ Replace the PC Board (Power side).
|
Turn off the power
|
||
|
H09
|
Open circuit of the PC Board's communication line
|
Won't communicate between the main micro processor and the indication micro processor.
|
■ Check if lead wire condition of PC Board between power and operation side, and replace one of PC Boards.
|
Remove the power plug
|
||
|
H17
|
Open circuit or short circuit of the thermistor TH4
|
Detect abnormal signal from the thermistor TH4
|
■ Check if condition of the connectors.
■ Replace the thermistor TH4
|
Turn off the power
|
||
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||