F01 .Motor triac short circuit.Check motor,module and wiring.
F02 . Motor jammed / tacho detached.Check motor,module and wiring.
F03 . Ntc short/open circuit. Check thermister,module wiring.
F05 . Pressure switch jammed on full or pump blocked.Check pump and switch.
F06 .Door lock doesn`t open/close.Check door lock ,wiring and pcb
F07.Heater relay stuck. Check module and wash heater.
F08 .Heater relay stuck. Check pressure switch,heater,module and wiring.
F09 .Setup error. Check eeprom.
F11 .Pump cannot be activated.Check Pump and wiring.
F12 .No communication between cards.Check module,top pcb and wiring.
F13 . High temperature rise in drying.Check fan ,dryer ntc,heater box for blockages.
F15 .Dryer heater fault.Check dryer element and pcb.
F18 .Fault on control board.Check pcb.