E11 ( fill time too long. )
E13 ( water leak in tub or air leak in air bell )
E21 ( Water not pumping out fast enough )
E23 ( Drain pump relay on control board failed or wire off pump )
E24 ( Drain pump relay on control board failed or wire off pump )
E31 ( Pressure sensor not communicating with control board )
E35 ( Pressure sensor indicates water overfill )
E36 ( control board problem ,replace control )
E41 ( Control board thinks the door switch is open )
E43 ( Control board problem ) Replace
E44 ( Control board problem ) Replace
E45 ( Control board problem ) Replace
E46 ( Control board problem ) Replace
E47 ( Board thinks the door PTC circuit is open in spin )
E48 ( Board thinks the door PTC circuit is closed )
E52 ( Bad signal from tacho generator )
E56 ( High motor current )
E57 ( High current on motor phase )
E59 ( No tacho signal for 3 seconds )
E5A ( High temp on heat sink caused by overloading. Replace speed control board)
E5B ( High temp on heat sink, replace speed control board)
E5C ( High temp on heat sink, replace speed control board)
E5D ( Communication problem )
E5E ( Communication problem )
E5F ( Communication problem )
E66 ( Heating element relay failure )
E67 ( Input voltage on microprocessor incorrect )
E68 ( Current leakage to ground on heater or fuse opened )
E70 ( The control board is not seeing the correct water supply )
E71 ( Wash NTC failure. (Tub heater) Replace control board or wire. )
E74 ( Wash temperature does not increase. Place NTC in correct position )
E75 ( Water temperature sensor circuit )
E76 ( NTC temperature for the cold water valve over the limits. Hot and cold-water hoses switched )
E82 ( Console control problem . Replace control board )
E83 ( Console control problem. Replace control board )
E91 ( Communication error between UI board and control board. Check wiring )
E93 ( Console control problem. Replace control board )
E94 ( Console control problem. Replace control board )
E95 ( Communication error. Replace control board )
E97 ( Console control problem. Replace control board )
E98 ( Console control problem. Replace control board )
EB1 ( Incoming power frequency out of limits. )
EB2 ( Incoming line voltage above 130 vac. Check voltage If below 130 replace control )
EB3 ( Incoming line voltage below 90 VAC. Check voltage if above 90 replace control )
EF1 ( Clogged drain pump )
EF2 ( Too much soap. advise to reduce soap)
EBE ( Console control problem .Replace control board )
EBF ( Console control problem . Replace control board )
EF5 ( NTC temperature for the hot water valve over the limits.Hot and cold hoses switched)