ERROR CODE | Times the LED FLASHES |
Seconds the LED stays OFF |
MOST PROBABLE REASON FOR THE ISSUING OF ERROR CODE: |
ERROR 01 | 1 | 5 | Door Safety Device/Drum’s Braking device defective and/or Wiring. |
ERROR 02 | 2 | 5 | The Water Fill Phase was not completed within the designed limit time.Defective Solenoid Valve,Pressostat,Water Fill Hose,Low Water Pressure in the network and/or Wiring. |
ERROR 03 | 3 | 5 | The Water Drain Phase was not completed within the designed limit time.Clogged Filter,Drain Pump,Drain Hose,Wall Discharge and/or Wiring. |
ERROR 04 | 4 | 5 | Several(3)interventions by the Anti-flood Safety Contact of Pressostat.Solenoid Valve blocked opened,defective Pressostat and/or Wiring. |
ERROR 05 | 5 | 5 | NTC Temperature Reading Probe opened or shorted and/or Wiring. |
ERROR 06 | 6 | 5 | Eeprom – Defective „Cuore” Control Module and/or Wiring. |
ERROR 07 | 7 | 5 | Jammed Motor’s Rotor and/or Wiring. |
ERROR 08 | 8 | 5 | Defective Tachometric Dynamo (opened or shorted) and/or Wiring. |
ERROR 09 | 9 | 5 | Defective „Cuore” Control Module (damaged Motor’s TRIAC) and/or Wiring. |
ERROR 10 | 10 | 5 | Missing dialogue between „Cuore” Control Module and Display board and/or Wiring. |
ERROR 12 | 12 | 5 | Missing dialogue between „Cuore” Control Module and Display board and/or Wiring. |
ERROR 14 | 14 | 5 | Missing Water Heating: defective NTC Probe and/or defective Water Heating Element and/or Wiring. |
ERROR 15 | 15 | 5 | Defective „Cuore” Control Module – Not Programmed „Cuore” Control Module. |
ERROR 16 | 16 | 5 | Water Heating Element is short circuited or defective electrical insulation. |
ERROR 17 | 17 | 5 | Wrong signal from Tachometric Dynamo. |
ERROR 18 | 18 | 5 | Defective „Cuore” Control Module and/or Wiring – Wrong Network Frequency. |