E11 ( fill time too long. ) E13 ( water leak in tub or air leak in air bell ) E21 ( Water not pumping out fast enough ) E23 ( Drain pump relay on control board failed or wire off pump ) E24 ( Drain pump relay on control board failed or wire off pump ) E31 ( Pressure sensor not communicating with control board ) E35 ( Pressure sensor indicates water overfill ) E36 ( control board problem ,replace control ) E41 ( Control board thinks the door switch is open ) E43 ( Control board problem ) Replace E44 ( Control board problem ) Replace E45 ( Control board problem ) Replace E46 ( Control board problem ) Replace E47 ( Board thinks the door PTC circuit is open in spin ) E48 ( Board thinks the door PTC circuit is closed ) E52 ( Bad signal from tacho generator ) E56 ( High motor current ) E57 ( High current on motor phase ) E59 ( No tacho signal for 3 seconds ) E5A ( High temp on heat sink caused by overloading. Replace speed control board) E5B ( High temp on heat sink, replace speed control board) E5C ( High temp on heat sink, replace speed control board) E5D ( Communication problem ) E5E ( Communication problem ) E5F ( Communication problem ) E66 ( Heating element relay failure ) E67 ( Input voltage on microprocessor incorrect ) E68 ( Current leakage to ground on heater or fuse opened ) E70 ( The control board is not seeing the correct water supply ) E71 ( Wash NTC failure. (Tub heater) Replace control board or wire. ) E74 ( Wash temperature does not increase. Place NTC in correct position ) E75 ( Water temperature sensor circuit ) E76 ( NTC temperature for the cold water valve over the limits. Hot and cold-water hoses switched ) E82 ( Console control problem . Replace control board ) E83 ( Console control problem. Replace control board ) E91 ( Communication error between UI board and control board. Check wiring ) E93 ( Console control problem. Replace control board ) E94 ( Console control problem. Replace control board ) E95 ( Communication error. Replace control board ) E97 ( Console control problem. Replace control board ) E98 ( Console control problem. Replace control board ) EB1 ( Incoming power frequency out of limits. ) EB2 ( Incoming line voltage above 130 vac. Check voltage If below 130 replace control ) EB3 ( Incoming line voltage below 90 VAC. Check voltage if above 90 replace control ) EF1 ( Clogged drain pump ) EF2 ( Too much soap. advise to reduce soap) EBE ( Console control problem .Replace control board ) EBF ( Console control problem . Replace control board ) EF5 ( NTC temperature for the hot water valve over the limits.Hot and cold hoses switched)
Mennyire volt hasznos ez a bejegyzés?
Kattintson egy csillagra az értékeléshez!
Átlagos értékelés / 5. Szavazatok száma:
Eddig nincs szavazat! Legyen Ön az első, aki értékeli ezt a bejegyzést.
A jobb felhasználói élmény érdekében az oldalon cookie-kat használunk. Oldalunk használatával, Ön elfogadja a cookie-k használatát.OK