E11     ( fill time too long. )
E13      ( water leak in tub or air leak in air bell )
E21      ( Water not pumping out fast enough )
E23      ( Drain pump relay on control board failed or wire off pump )
E24      ( Drain pump relay on control board failed or wire off pump )
E31      ( Pressure sensor not communicating with control board )
E35      ( Pressure sensor indicates water overfill )
E36      ( control board problem ,replace control )
E41      ( Control board thinks the door switch is open )
E43      ( Control board problem ) Replace
E44      ( Control board problem ) Replace
E45      ( Control board problem ) Replace
E46      ( Control board problem ) Replace
E47      ( Board thinks the door PTC circuit is open in spin )
E48       ( Board thinks the door PTC circuit is closed )
E52       ( Bad signal from tacho generator )
E56       ( High motor current )
E57       ( High current on motor phase )
E59       ( No tacho signal for 3 seconds )
E5A       ( High temp on heat sink caused by overloading. Replace speed control board)
E5B       ( High temp on heat sink, replace speed control board)
E5C       ( High temp on heat sink, replace speed control board)
E5D       ( Communication problem )
E5E       ( Communication problem )
E5F       ( Communication problem )
E66       ( Heating element relay failure )
E67       ( Input voltage on microprocessor incorrect )
E68       ( Current leakage to ground on heater or fuse opened )
E70       ( The control board is not seeing the correct water supply )
E71       ( Wash NTC failure. (Tub heater) Replace control board or wire. )
E74       ( Wash temperature does not increase. Place NTC in correct position )
E75       ( Water temperature sensor circuit )
E76       ( NTC temperature for the cold water valve over the limits. Hot and cold-water hoses switched )
E82       ( Console control problem . Replace control board )
E83       ( Console control problem. Replace control board )
E91       ( Communication error between UI board and control board. Check wiring )
E93       ( Console control problem. Replace control board )
E94       ( Console control problem. Replace control board )
E95       ( Communication error. Replace control board )
E97       ( Console control problem. Replace control board )
E98       ( Console control problem. Replace control board )
EB1       ( Incoming power frequency out of limits. )
EB2       ( Incoming line voltage above 130 vac. Check voltage If below 130 replace control )
EB3       ( Incoming line voltage below 90 VAC. Check voltage if above 90 replace control )
EF1       ( Clogged drain pump )
EF2       ( Too much soap. advise to reduce soap)
EBE       ( Console control problem .Replace control board )
EBF       ( Console control problem . Replace control board )
EF5       ( NTC temperature for the hot water valve over the limits.Hot and cold hoses switched)