Háztartási gép szerviz Budapesten és Pest megyében
Budapesten és Pest megyében

Whirlpool szárítógép

Whirlpool cabrio dryer error codes

DISPLAYDESCRIPTIONEXPLANATION / RECOMMENDED PROCEDURE
PFPower FailurePF flashes to indicate that a power failure occurred while the dryer was running. Press START to continue the cycle, or press PAUSE/CANCEL to clear the display.
AFRestricted Airflow ConditionAF flashes if a restricted airflow condition exists. Check to make sure the lint screen is dean, the door seal is in place and the vent is not obstructed.
F-01Primary Control FailureF-01 flashes when there is a primary control failure. Replace the machine control electronics. See Accessing & Removing the Electronic Assemblies.
F-02Keypad/ User Interface FailureF-02 flashes when there is a stuck button or user interface mismatch. This fault code will ONLY appear when in the diagnostic test mode.
F-20Heater #1 FailureF-20 flashes when there is a heater 1 failure.
F-21Heater #2 FailureF-21 flashes when there is a heater 2 failure (dual element models).
F-22Exhaust Thermistor OpenF-22 flashes if the exhaust thermistor is open.
F-23Exhaust Thermistor ShortedF-23 flashes if the exhaust thermistor has shorted.
F-24Inlet Thermistor OpenF-24 flashes if the inlet thermistor is open. This fault code will ONLY appear when in the diagnostic test mode.
F-25Inlet Thermistor ShortedF-25 flashes if the inlet thermistor is shorted. This fault code will ONLY appear when in the diagnostic test mode.
F-26Motor Drive System FailureF-26 flashes if there is a motor drive system failure.
F-28Moisture Sensor OpenF-28 flashes if the moisture sensor strip is open. This fault code will ONLY appear when in the diagnostic test mode.
F-29Moisture Sensor ShortedF-29 flashes if the moisture sensor strip has shorted. This fault code will ONLY appear when in the diagnostic test mode.
F-30Restricted Airflow ConditionF-30 flashes if a restricted airflow condition exists. This fault code will ONLY appear when in the diagnostic test mode. Check to make sure the lint screen is clean, the door seal is in place and the vent is not obstructed.

Whirlpool duet dryer error codes

CodeDescriptionExplanation and Recommended Procedure
FlElCycle Control Unit (CCU) ProblemIndicates a CCU problem.
• Verify all connections to and from the CCU.
F2E1User Interface (Ul) Problem (stuck button)Indicates a stuck button (depressed for over 20 seconds) or Ul mismatch. This fault code will ONLY appear when in the service diagnostic mode.
F3E1Outlet Thermistor OpenIndicates that the outlet thermistor is open. Temperature drops below 18° F (> 50k ohms).
F3E2Outlet Thermistor ShortedIndicates that the outlet thermistor has shorted. Temperature above 250° F (< 500 ohms).
F3E5Compressor and Outlet Thermistors OpenIndicates that the Compressor and Outlet Thermistors are open. Will occur if the P14 connector is not plugged into the CCU.
F3E6Moisture Sensor OpenIndicates the moisture sensor strip is open. This fault code will ONLY appear when in the service diagnostic mode.
F3E7Moisture Sensor ShortedIndicates that the moisture sensor strip has shorted. This fault code will ONLY appear when in the service diagnostic mode.
F3E8Compressor Sensor OpenIndicates that the compressor sensor is open. This fault code will stop the dryer.
F3E9Compressor Sensor ShortedIndicates that the compressor sensor has shorted. This fault code will stop the dryer.
F4E1Heater Relay or Connector ProblemIndicates no voltage detected at the heater relay. This fault code appears ONLY when in the Diagnostic Test Mode.
  • Unplug dryer or disconnect power and check that the wires are plugged into the heater element(s) and the relay(s) on the CCU.
F4E3Restricted Air Flow’Indicates low air flow that may affect dryer performance.
  • Confirm that airflow system is not blocked; check lint screen, secondary lint filter, and exhaust fan.
()

F01 Main relay failure
Potential causes
Main relay defective, replace control board
Short circuit between heating element and ground

F02 EEPROM failure
Potential causes
Disturbance in the EEPROM re-program with SAM

F03 System failure
Potential causes
Check humidity sensor and the respective wiring and connections
Disturbance in control boaro

F04 Heater relay failure
Potential causes
Defective heater relay(s), before replacing the timer carry out the reset procedure
Grounding isaue on heating element
Open thermostat on heating element

F05 NTC 1 (air channel) failure
Potential causes
NTC 1 out of tolerance, shortage or open circuit
Electrical connection between NTC 1 and control unit
Ambient Temperature is out of dryer specification
Reset procedure needed if shortage was cause (refer to bottom)

F06 NTC 2 (heater) failure
Potential causes
NTC 2 out of tolerance, shortage or open circuit
Electrical connection between N”C 2 and control unit
Ambient Temperature is out of dryer specification
Reset procedure needed if shortage was cause (refer to bottom)

F07 Drum sensor failure
Potential causes
Drum sensor defective
Magnet not in correct position or missing
Electrical connection between reed switch and control board
Drum doesn’t turn
Carry out reset procedure (refer to bottom)

F10 MCU communication error
Potential causes
Electrical connection between MCU and control board
Communication error between MCU and con1roI board

F1 1
MCU motor failure:
-3′ Reserved not supported

F12 MCU not initialised
Potential causes
MCU initialised not correctly
Switch appliance off and again on
Wrong Software on CCU, re—program ,hex file

F14
MCU failure / low voltage detection
Potential causes
Low voltage detection on communication bus MCU,’”CCU

F15 MCU failure
Potential causes
Hardware failure on MCU
MCU software looses control on rotor position.(locked condition)

F18 MCU failure / MCU over temperature
Potential causes
Temperature of the MCU ( power module IC )is too high
Motor cannot be started for more than 20 s

F19
MCU failure / over voltage detection
Potential causes
High voltage detection on communication bus

F20
Motor overheating:
-9′ Reserved not supported

F21 UI communication error
Potential causes
Communication between control board and user interface not possible
Disturbance in cDnnection of control board and user interface

F22
MCU over current detection
Potential causes
Current limiter on MCU detect over current, overload of motor

Mennyire volt hasznos ez a bejegyzés?

Kattintson egy csillagra az értékeléshez!

Átlagos értékelés / 5. Szavazatok száma:

Eddig nincs szavazat! Legyen Ön az első, aki értékeli ezt a bejegyzést.