Whirlpool Induction Hob Error Codes

Error Code Fault
F Sensor
F3 Configuration Sensor
F12 Communication Sensor
F22 Key Sensitivity Error

Whirlpool Touch Control Hob Error Codes

Error Code Fault
F3 Configuration Sensor
F12 WISP Communication Error
F22 Key Sensitivity Error

Whirlpool Microwave Error Codes

Error Code Fault
ERR0 Convection temperature fault, not connected or short circuit
ERR1 Short circuit in the Microwave Relay
ERR3 Key error when one of the buttons is pressed for more than 1 minute
ERR6 Weight sensor calibration has not been performed
ERR7 Humidity sensor is defective or has not been connected
ERR8 Impossible to write to E2 EEPROM
ERR9 Option has not been set
ERR A No wheel detected on weight sensor
ERR B No pulses from the weight sensor or <4267Hz
ERR C Fuzzy temperature sensor fault not 19-41C
ERR D NTC Overheat protection on the Magnetron is faulty (O/C or S/C)

Whirlpool Steam Chef Error Codes

Error Code Fault
F0 Incorrect value of cavity sensor
F1 Incorrect value of cavity sensor
F2 Incorrect value of food probe
F3 Incorrect value of climate sensor
F4 Incorrect current value from flap motor
F5 Unable to backup EEPROM
F7 No, or slow increase of climate temperature
F8 Fuzzy temperature sensor fault not 19-41C
F9 Fuzzy temperature sensor fault not 19-41C
No indication Oven does not heat

Whirlpool Smart Gas Error Codes

Error Code Fault
F01 On/off valve stuck open
F02 Communication problem
F03 Control board problem
F04 User interface problem
F05 Continuous E2 EEPROM reset
F11 Burner 1 open circuit on thermocouple
F21 Burner 2 open circuit on thermocouple
F31 Burner 3 open circuit on thermocouple
F41 Burner 4 open circuit on thermocouple
F12 Burner 1 PWM valve stuck open
F22 Burner 2 PWM valve stuck open
F32 Burner 3 PWM valve stuck open
F42 Burner 4 PWM valve stuck open

Whirlpool Side by Side Error Codes

Display LED Buzzer Error
D Fdg On On Damper stuck, doesn’t connect
C Fdg On On Fridge sensor failure
C Fzr On On Freezer sensor failure
CF Fzr On On Communication failure between main board and interface
„-” Fzr On On Temperature in freezer is higher than -11 degrees C (safety limit)
„-7” or other values on freezer On On Black out over temperature alarm engaged

Whirlpool Oven Error Codes

Error Code Error Solution
F01 O/C or S/C temperature probe Replace temperature probe
F02 Oven overheating Replace capricorn
F03 Capricorn not properly configured Replace capricorn
F04 WISP protocol not working Replace capricorn or scale

Szárítógép dupla hibakódos

 

Szárítógép egy hibakódos

Szárítógép
F01 Main relay failure
Potential causes
Main relay defective, replace control board
Short circuit between heating element and ground
F02 EEPROM failure
Potential causes
Disturbance in the EEPROM re-program with SAM
F03 System failure
Potential causes
Check humidity sensor and the respective wiring and connections
Disturbance in control boaro
F04 Heater relay failure
Potential causes
Defective heater relay(s), before replacing the timer carry out the reset procedure
Grounding isaue on heating element
Open thermostat on heating element
F05 NTC 1 (air channel) failure
Potential causes
NTC 1 out of tolerance, shortage or open circuit
Electrical connection between NTC 1 and control unit
Ambient Temperature is out of dryer specification
Reset procedure needed if shortage was cause (refer to bottom)
F06 NTC 2 (heater) failure
Potential causes
NTC 2 out of tolerance, shortage or open circuit
Electrical connection between N”C 2 and control unit
Ambient Temperature is out of dryer specification
Reset procedure needed if shortage was cause (refer to bottom)
F07 Drum sensor failure
Potential causes
Drum sensor defective
Magnet not in correct position or missing
Electrical connection between reed switch and control board
Drum doesn’t turn
Carry out reset procedure (refer to bottom)
F10 MCU communication error
Potential causes
Electrical connection between MCU and control board
Communication error between MCU and con1roI board
F1 1
MCU motor failure:
-3′ Reserved not supported
F12 MCU not initialised
Potential causes
MCU initialised not correctly
Switch appliance off and again on
Wrong Software on CCU, re—program ,hex file
F14
MCU failure / low voltage detection
Potential causes
Low voltage detection on communication bus MCU,’”CCU
F15 MCU failure
Potential causes
Hardware failure on MCU
MCU software looses control on rotor position.(locked condition)
F18 MCU failure / MCU over temperature
Potential causes
Temperature of the MCU ( power module IC )is too high
Motor cannot be started for more than 20 s
F19
MCU failure / over voltage detection
Potential causes
High voltage detection on communication bus
F20
Motor overheating:
-9′ Reserved not supported
F21 UI communication error
Potential causes
Communication between control board and user interface not possible
Disturbance in cDnnection of control board and user interface
F22
MCU over current detection
Potential causes
Current limiter on MCU detect over current, overload of motor

Mennyire volt hasznos ez a bejegyzés?