Whirlpool Induction Hob Error Codes
Error Code |
Fault |
F |
Sensor |
F3 |
Configuration Sensor |
F12 |
Communication Sensor |
F22 |
Key Sensitivity Error |
Whirlpool Touch Control Hob Error Codes
Error Code |
Fault |
F3 |
Configuration Sensor |
F12 |
WISP Communication Error |
F22 |
Key Sensitivity Error |
Whirlpool Microwave Error Codes
Error Code |
Fault |
ERR0 |
Convection temperature fault, not connected or short circuit |
ERR1 |
Short circuit in the Microwave Relay |
ERR3 |
Key error when one of the buttons is pressed for more than 1 minute |
ERR6 |
Weight sensor calibration has not been performed |
ERR7 |
Humidity sensor is defective or has not been connected |
ERR8 |
Impossible to write to E2 EEPROM |
ERR9 |
Option has not been set |
ERR A |
No wheel detected on weight sensor |
ERR B |
No pulses from the weight sensor or <4267Hz |
ERR C |
Fuzzy temperature sensor fault not 19-41C |
ERR D |
NTC Overheat protection on the Magnetron is faulty (O/C or S/C) |
Whirlpool Steam Chef Error Codes
Error Code |
Fault |
F0 |
Incorrect value of cavity sensor |
F1 |
Incorrect value of cavity sensor |
F2 |
Incorrect value of food probe |
F3 |
Incorrect value of climate sensor |
F4 |
Incorrect current value from flap motor |
F5 |
Unable to backup EEPROM |
F7 |
No, or slow increase of climate temperature |
F8 |
Fuzzy temperature sensor fault not 19-41C |
F9 |
Fuzzy temperature sensor fault not 19-41C |
No indication |
Oven does not heat |
Whirlpool Smart Gas Error Codes
Error Code |
Fault |
F01 |
On/off valve stuck open |
F02 |
Communication problem |
F03 |
Control board problem |
F04 |
User interface problem |
F05 |
Continuous E2 EEPROM reset |
F11 |
Burner 1 open circuit on thermocouple |
F21 |
Burner 2 open circuit on thermocouple |
F31 |
Burner 3 open circuit on thermocouple |
F41 |
Burner 4 open circuit on thermocouple |
F12 |
Burner 1 PWM valve stuck open |
F22 |
Burner 2 PWM valve stuck open |
F32 |
Burner 3 PWM valve stuck open |
F42 |
Burner 4 PWM valve stuck open |
Whirlpool Side by Side Error Codes
Display |
LED |
Buzzer |
Error |
D Fdg |
On |
On |
Damper stuck, doesn’t connect |
C Fdg |
On |
On |
Fridge sensor failure |
C Fzr |
On |
On |
Freezer sensor failure |
CF Fzr |
On |
On |
Communication failure between main board and interface |
„-” Fzr |
On |
On |
Temperature in freezer is higher than -11 degrees C (safety limit) |
„-7” or other values on freezer |
On |
On |
Black out over temperature alarm engaged |
Whirlpool Oven Error Codes
Error Code |
Error |
Solution |
F01 |
O/C or S/C temperature probe |
Replace temperature probe |
F02 |
Oven overheating |
Replace capricorn |
F03 |
Capricorn not properly configured |
Replace capricorn |
F04 |
WISP protocol not working |
Replace capricorn or scale |
Szárítógép dupla hibakódos
Szárítógép egy hibakódos
Szárítógép
F01 Main relay failure
Potential causes
Main relay defective, replace control board
Short circuit between heating element and ground
F02 EEPROM failure
Potential causes
Disturbance in the EEPROM re-program with SAM
F03 System failure
Potential causes
Check humidity sensor and the respective wiring and connections
Disturbance in control boaro
F04 Heater relay failure
Potential causes
Defective heater relay(s), before replacing the timer carry out the reset procedure
Grounding isaue on heating element
Open thermostat on heating element
F05 NTC 1 (air channel) failure
Potential causes
NTC 1 out of tolerance, shortage or open circuit
Electrical connection between NTC 1 and control unit
Ambient Temperature is out of dryer specification
Reset procedure needed if shortage was cause (refer to bottom)
F06 NTC 2 (heater) failure
Potential causes
NTC 2 out of tolerance, shortage or open circuit
Electrical connection between N”C 2 and control unit
Ambient Temperature is out of dryer specification
Reset procedure needed if shortage was cause (refer to bottom)
F07 Drum sensor failure
Potential causes
Drum sensor defective
Magnet not in correct position or missing
Electrical connection between reed switch and control board
Drum doesn’t turn
Carry out reset procedure (refer to bottom)
F10 MCU communication error
Potential causes
Electrical connection between MCU and control board
Communication error between MCU and con1roI board
F1 1
MCU motor failure:
-3′ Reserved not supported
F12 MCU not initialised
Potential causes
MCU initialised not correctly
Switch appliance off and again on
Wrong Software on CCU, re—program ,hex file
F14
MCU failure / low voltage detection
Potential causes
Low voltage detection on communication bus MCU,’”CCU
F15 MCU failure
Potential causes
Hardware failure on MCU
MCU software looses control on rotor position.(locked condition)
F18 MCU failure / MCU over temperature
Potential causes
Temperature of the MCU ( power module IC )is too high
Motor cannot be started for more than 20 s
F19
MCU failure / over voltage detection
Potential causes
High voltage detection on communication bus
F20
Motor overheating:
-9′ Reserved not supported
F21 UI communication error
Potential causes
Communication between control board and user interface not possible
Disturbance in cDnnection of control board and user interface
F22
MCU over current detection
Potential causes
Current limiter on MCU detect over current, overload of motor